1.
Conductor
2.
Insulation
3.
Outer sheath
4.
Identification thread
APPLICATION: Suitable for power
transmission and transmission of signals and commands for crane hoists and
cranes in installations in which the free length suspended not exceeding 35
meters and the speed is not greater than 1.6 m/s.
INSTALLATION: For mobile
installations where the inside temperature remains between 0 ° C and 40 ° C. You
should take care to carry the cable so as to avoid
torsion or twisting. Cable
types for conditions outside these limits are subject to agreement between
buyer and supplier.
Full characteristics here!
FRORAR 450/750 V O.R.
1.
Conductors
2.
Insulation
3.
Inner sheath
4.
Armouring
5.
Outer sheath
APPLICATION: Suitable for power
transmission and transmission of signals and controls the connections of
machinery and equipment generally where you need a certain degree of protection
against rodents and termites.
INSTALLATION: For
fixed installation in ordinary or damp environments and temporarily outside.
Can be installed on bridges, pipes, conduits and similar systems. Not for
laying underground.
Full characteristics here!
LiYCY 450/750 V O.R.
1.
Conductor
2.
Insulation
3.
Assembling
4.
Shield
5.
Outer sheath
APPLICATION: Suitable for the transmission
of signals and commands for the interconnection of instrumentation and control
systems with digital or analog signal transmission, which requires a degree of
protection against electromagnetic interference.
INSTALLATION: For
fixed installation in ordinary or damp environments and temporarily outside.
Can be installed on bridges, pipes, conduits and similar systems. Not for
laying underground.
Full characteristics here!
SOLAR CABLE ARMOURED 0,6/1 kV
1.
Conductor
2.
Insulation
3.
Assembling
4.
Armour
5.
Outer sheath
APPLICATION: Suitable for the
interconnection of the components of PV systems are characterized by: best
mechanical properties for a range of temperature from - 40 to + 90 ° C, high
abrasion resistance, laceration, UV, ozone, water, flame propagation, low
smoke, halogen-free, weather resistance that allows a period of at least the
life of the photovoltaic. Ensure adequate protection against rodents and
termites.
INSTALLATION: For
fixed installation inside and outside, without protection or in pipes, embedded
or closed systems. It's for laying underground direct or indirect.
Full characteristics here!
FG7OHH2R 0,6/1 kV
1.
Conductor
2.
Insulation
3.
Inner sheath
4.
Al/Pet tape
5.
Copper braid
6.
Outer sheath
APPLICATION: Suitable for the transport
of energy and in particular for photovoltaic systems
for the connection between the inverter and power supply.
INSTALLATION: For
fixed installation inside and outside even in wet environments. Can be
installed on walls or metal structures, on platforms, pipes, conduits and
similar systems. For laying underground direct or indirect.
Full characteristics here!